Search published articles


Showing 2 results for 4v Alloy

Hosseini Sh., Arabi H., Tamizifar M., Zeyaei A.a.,
Volume 3, Issue 1 (6-2006)
Abstract

In this research, rotating bending fatigue test at minimum to maximum stress ratio of R=-1 was used for investigating the fatigue behavior of Ti-6Al-4V alloy. Both smooth and notched specimens, with elastic concentration factor, kt, of approximately 3.6 and 4.1 were used for this purpose.In addition, the effect of variation in ultimate tensile strength, UTS, on the fatigue behavior of this alloy was studied. S-N curves were drawn and the value of notch sensitivity was obtained or each case.The results showed that the presence of notch in Ti-6Al-4V alloy has a different amount of sensitivity when the notched specimens were subjected to high cycle fatigue (HCF) and low cycle fatigue (LCF) tests. However, the notch sensitivity of this alloy was shown generally to be much lower than steel alloys with similar UTS values. Thus, considering the high compatibility of this alloy with the body environment and its low sensitivity to notch, one can strongly recommend this alloy for use in biomedical application.
N. Nikoogoftar, S. H. Razavi, M. Ghanbari,
Volume 14, Issue 3 (9-2017)
Abstract

In this research, the effect of annealing and aging temperature as well as the effect of quenching media on the microstructure, hardness and dry sliding wear behavior of Ti-6Al-4V alloy has been studied. Cylindrical samples with the diameter of 10 mm and the height of 20mm were solutionized at 930˚C and 1060˚C for 600 seconds and then were quenched in the cold water and in the air. The samples were aged at different temperature of 480˚C, 550˚C and 610˚C for 360 s to increase the hardness. Heat treated samples were tested using standard pin-on-disc test machine at the applied loads of 100, 150 and 200 N. Microstructural investigations using scanning electron microscope revealed that for the samples solutionized at 930˚C and quenched in the water, the microstructure is composed of primary α and high volume fraction of martensitic α΄ phase with fine precipitated of β between martensitic lathes. In the case of air cooled samples, transformed β has also been  appeared in the vicinity of primary α. For the samples solutionized at 1060˚C and quenched in the water, fully martensitic micro structure with fine β precipitates was observed. For the sample solutionized at 1060˚C and air quenched, plate like α and lamellar grain boundary β were detected. The maximum hardness value relates to the sample solutionized at 1060˚C and quenched in water which is equal to 433 HV. Different wear mechanisms, including oxidative wear, scratch, and delamination occurred at the worn surfaces at different applied loads. For the samples quenched in the water, the oxidative wear mechanism governing at low applied load and oxide debris was observed as separate or compacted particles which formed in the contact between pin and steel counter face detached from the sample. At higher applied loads, delamination and scratch mechanism was also observed and metallic plate like debris was detached from the sample. Mechanically mixed layer (MML) was formed on the surface of the pin at high applied loads and for the samples with low hardness value adhesion marks were also revealed on the steel disc. The minimum weight loss in the wear test is related to the sample quenched from the 1060ºC in the cold water and aged at 550 ºC .  



Page 1 from 1     

© 2022 All Rights Reserved | Iranian Journal of Materials Science and Engineering

Designed & Developed by : Yektaweb